Service Mode

Lamp

Lamp information light output switching.

All information about the lamp is stored inside the lamp house and can be displayed via the projector software on the projection screen. No information can be changed.

The Constant light output function can be changed between yes and no.

How to display the lamp menu.

1Push the cursor key or to highlight 'Lamp' (menu 1).

2 Press ENTER to select.

The lamp menu will be displayed (menu 2)

Which information is available ?

Serial number : unique serial number of the lamp.

Type : lamp type.

Run time : total time the lamp is used in this or other projectors.

Remaining run time : time left before the lamp must be replaced

Using the lamp longer than the maximum run time (1500 hours) may damage the projector.

Number of strikes : Total times the lamp is started up.

Z-AXIS : indication to adjust the Z-AXIS of the lamp (see Re-adjustment of the lamp position in chapter Installation Guidelines).

SERVICE

IDENTIFICATION

CHANGE PASSWORD CHANGE LANGUAGE CHANGE PROJ. ADDRESS SERIAL COMMUNICATION

LAMP

MORE...

Select with or

then <ENTER> <EXIT> to return.

LAMP

Constant light output [YES]

Serial number : R101111

Article number : R9840740

Run time : 10 hours

Remaining run time : 490 hours

Number of strikes : 10

Z-AXIS : 100

Select with or <ENTER> to toggle <EXIT> to return.

menu1

menu2

How to switch the constant light output ?

1Push the cursor key or to highlight 'Constant Light Output' (menu 1).

2 Press ENTER to toggle between [YES] and [NO]. [YES] : constant light output, power will be adapted. [NO] : fixed power, no power adaptation.

BARCO logo

What can be done ?

The BARCO logo can be added to the image, in overlay or on a background, on any place on the screen.

How to add or the change the settings ?

To add the BARCO logo or to change a setting in the BARCO logo menu:

1Push the cursor key or to highlight 'BARCO logo' (menu 1).

2 Press ENTER to select.

The BARCO logo menu will be displayed on the screen (menu 2. Within this menu, three toggle settings and a shift control are available.

SERVICE

BARCO LOGO

ADD-INS

PRESET INPUT BALANCE

DIAGNOSIS

MORE...

Select with or

then <ENTER>

<EXIT> to return.

menu1

BARCO LOGO

STATUS : [ON]

BACKGROUND : [ON]

SHIFT

HOT KEY : [TEXT]

Select with or

then <ENTER>

<EXIT> to return.

menu2

R5976336 BARCOSLM R6 Executive 06092001

 

9-7

 

Page 74
Image 74
Barco R9002790 Lamp information light output switching, How to display the lamp menu, Which information is available ?