Configuration using the PC

3-17

Signal

If a DTMF tag is programmed for a point and the Signal command is set, then only the DTMF tag for this point will be sent and the voice message will not be spoken.

Signal must be preceded by a Dial command; it cannot be the first entry in the list. It can be used once in a list.

Delete

Delete removes the selected command from the list. Commands that followed the deleted one are moved to fill in the empty space. If the first command is selected, then Delete will remove all commands for this line.

3.5.5 General

Settings that affect the overall operation of the Cv2 are entered in the General section.

Site Name

The Site Name is a 16 character text field that allows you to enter a description of the site where the Cv2 is to be located. Other than viewing in the General dialog box, this name has no other use. Normally it is set to match the voice message that is programmed as the Site Identifier.

Default Site Name: an empty text string.

Security Level

The Security level setting determines the actions that the Cv2 will perform when it receives an incoming call.

Level 1

The Cv2 announces the Site ID, any groups that are in the alarm state

 

and prompts the caller to “Enter Command Code”.

Level 2

When the incoming call is answered by the Cv2, only the Site ID is

 

announced; for further access to the Cv2 the caller must enter the

 

Access Code.

Level 3

An incoming call results in the Cv2 coming off-hook with no

 

announcement; the Access Code must be entered within ten seconds or

 

the Cv2 will hang up.

Default Security Level: Level 1

Access Code

If you plan to use the remote programming features where changes are made by calling the unit from a remote phone, an access code must be programmed.

For remote programming, all security levels require the Access code. For local programming, the Access code must be entered if the unit has this code. Local

B1272M001

BARNETT ENGINEERING LTD.

ProTalk Cv2

Page 31
Image 31