Temporary Base Unit --- If an assigned base unit fails, the next unit in the stack order automatically becomes the new temporary base unit. This change is indicated by the Base LED on the temporary base unit’s LED display panel turning on (yellow).

The automatic base unit change to the next unit in the stack order is a temporary safeguard which allows you time to replace the failed unit, or reassign the temporary base unit as the new base unit.

Note: If you do not reassign the temporary base unit as the new base unit, and the temporary base unit fails, the automatic failover to another temporary base unit will not occur.

Set the Unit Select switch on the temporary base unit to Base (up =Base) to reassign it as the new base unit.

Removing a unit from the stack--- if a unit is removed

from the stack (therefore operating in standalone mode), the following switch configuration settings revert back to the settings configured before the unit became a member of the stack:

IP address

console password

TELNET password

SNMP community strings