Bay Technical Associates 400-ST1 manual Proceed to Connecting Power on

Models: 400-ST1

1 40
Download 40 pages 45.9 Kb
Page 24
Image 24

b.Connect the other end of the cascade cable to the cascade A In connector on the unit just below the base unit (unit 2), or just above the base unit if cascading up the stack.

c.Continue attaching the cascade cables until the last unit is configured.

A maximum of eight units can be configured per stack.

d.At the last unit in the stack, connect one end of a cascade max-return cable to the Cascade A Out connector. Connect the other end of the cascade max-return cable to the cascade A In connector on the base unit.

When stacking 3 or more units, the (optional) 1 meter (39.27 inch) cascade max-return cable is required (Bay Networks Part Number 303979-A).

8.Be sure all cable connections to the cascade connectors are secured firmly by the thumb screws on the cascade cable plugs.

9.Proceed to “ Connecting Power” on page 23.

22

Page 24
Image 24
Bay Technical Associates 400-ST1 manual Proceed to Connecting Power on