LTO
LTO
TM
15
Parameter& Functions Set-up Guide
SelectMODE NEXTx3 .Press ENTER.
Youare first presented with the parameters relating to the Low-Pass Filter (LPF) of Output 1 (OP1) - see Fig.2.
Usethe arrow keys to select each parameter: (defaultis ), and
.The selected parameter will flash to show it is editable. Adjust the setting by using the rotary
control.
(Fig.2):For each filter there are 10 options plus (i.e. filter bypass):
type( )with 6dB, 12dB, 18dB or 24dB per octave slope
type( ) with 12dB, 18dB or 24dB per octave slope
type( )with 12dB, 24dB or 48dB* per octave slope
Choosingthe Linkwitz-Riley 48dB/octave filter will reduce the number of EQ bands available on that Output
channel.
(Fig.3):For each of the filters, the crossover point can be set between 15.6Hz and
16kHz.
Edit Xover
FilterType/Slope Thru CrossoverFrequency
SignalPhase
FilterType/Slope Thru
Butterworth But
Bessel Bes
Linkwitz-Riley LR
*
CrossoverFrequency
Fig.2
OP1
2k00
LPF Bes
Hz
24
Fig.3
OP1
1k46
LPF Thru
Hz 0
0