BENDIX SD-08-2414 manual Symptoms Cause Remedy, Perform tests 1 to 6 in the order presented

Models: SD-08-2414

1 30
Download 30 pages 41.54 Kb
Page 18
Image 18

BENDIX® AD-IP®AIR DRYER TROUBLESHOOTING CHART

SYMPTOMS

CAUSE

REMEDY

 

1. Air dryer is constantly

A. Excessive system leakage.

A. If leakage IS SHOWN on the gauges, test for

“cycling” or purging.

IMPORTANT: Note whether

excessive service brake system leakage.

Air dryer purges

air pressure loss is shown

Allowable leakage:

frequently (every four

on dash gauge(s). Pressure

Single vehicle - 1 psi/minute either service reservoir.

(4) minutes or less

loss SHOWN on gauges

Tractor trailer - 3 psi/minute either service reservoir.

while vehicle is idling).

is caused by service brake

 

system or component

Repair and retest as required.

 

leakage. Pressure loss

 

 

 

NOT SHOWN on gauges is

 

 

 

caused by supply system or

 

 

 

component leakage.

 

 

 

 

Dash

 

 

 

Gauge

Air pressure loss shown on

 

 

 

the dash gauges: test all

 

 

 

components, fittings and lines

 

 

Dash

in the service brake system

 

 

(from this point downstream).

 

 

Gauge

 

 

 

B. If leakage is NOT SHOWN on gauges test for

 

 

excessive supply system leakage.

Remove the drain cock, or valve, in the supply reservoir (wet tank) and install an air gauge. Build the system pressure and allow the air dryer to purge. Observe the air gauge in the supply reservoir. The pressure drop should not exceed 1 psi per minute.

Perform tests 1 to 6 in the order presented.

18

Page 18
Image 18
BENDIX SD-08-2414 manual Symptoms Cause Remedy, Perform tests 1 to 6 in the order presented