BENDIX® AD-IP®AIR DRYER TROUBLESHOOTING CHART

SYMPTOMS

CAUSE

REMEDY

1. Air dryer is constantly

A. Excessive system leakage.

6. With a gauge installed at the RES port of the

“cycling” or purging.

IMPORTANT: Note whether

governor, pressure should not drop below the “cut-in”

Air dryer purges

air pressure loss is shown

pressure at the onset of the compressor “unloaded”

frequently (every four

on dash gauge(s). Pressure

cycle. If the pressure drops, check for “kinks” or

(4) minutes, or less,

loss SHOWN on gauges

restrictions in the line connected to the RES port.

The line connected to the RES port on governor must

while vehicle is idling)

is caused by service brake

be the same diameter or preferably larger than the

(continued).

system or component

lines connected to UNL port(s) on governor.

 

leakage. Pressure loss

 

 

 

NOT SHOWN on gauges is

 

 

caused by supply system

 

 

or component leakage.

 

 

(continued)

 

 

B. Holset® “E” type compressor.

B. Test the Holset® E Compressor unloader system

 

 

with a feedback line and check valve for proper

 

 

operation. Make certain the Holset ECON is not in

 

 

use with the drop-in version of the air dryer, if so,

 

 

remove and retest.

 

 

When installing a Bendix® Drop-In air dryer in a system

 

 

equipped with a Holset E or QE compressor, remove

 

 

the Holset ECON valve along with its feedback and

 

 

governor control line.

Check Valve

Feedback Line

Typical Drop-In Air Dryer End Cover

20