STEP 3: MINIMUM FLAME ADJUSTMENT

STEP 3: MINIMUM FLAME ADJUSTMENT

WARNING!

These adjustments should be made only for use of the appliance with natural gas. For use with liquid propane gas, the choke screw must be fully turned in a clockwise direction.

SURFACE BURNERS

1.Light one burner at a time and set the knob to the MINIMUM position (small flame).

2.Remove the knob.

3.The range is equipped with a safety valve. Using a small‐size slotted screwdriver, locate the choke valve on the valve body and turn the choke screw to the right or left until the burner flame is adjusted to desired minimum.

4.Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.