10-4. TROUBLE CRITERION OF MAIN PARTS MUZ-FD09NAMUZ-FD12NA

Part name

 

Check method and criterion

 

 

 

 

 

 

 

Figure

Defrost thermistor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(RT61)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient temperature

Measure the resistance with a tester.

 

 

 

 

 

 

 

 

 

 

 

 

 

thermistor (RT65)

Refer to 10-6. “Test point diagram and voltage”,1. “Inverter P.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor heat ex-

board”, the chart of thermistor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

changer temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

thermistor (RT68)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Discharge tem-

Measure the resistance with a tester. Before measurement, hold the

 

 

 

 

 

 

 

 

 

 

 

 

 

perature thermistor

 

 

 

 

 

 

 

 

 

 

 

 

 

thermistor with your hands to warm it up.

 

 

 

 

 

 

 

 

 

 

 

 

 

(RT62)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fin temperature

Refer to 10-6. “Test point diagram and voltage”,1. “Inverter P.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

board”, the chart of thermistor.

 

 

 

 

 

 

 

 

 

 

 

 

 

thermistor (RT64)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure the resistance between terminals using a tester.

WHT

RED BLK

 

(Winding temperature : -4 ~ 104 °F (-20 ~ 40 °C))

 

 

 

 

 

 

 

2

 

 

 

3

 

 

1

Compressor

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U-V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U-W

 

1.52 ~ 2.17 Ω

 

 

V

 

 

 

 

U

 

 

 

 

 

V-W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure the resistance between lead wires using a tester.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Part temperature : 14 ~ 104 °F (-10 ~ 40 °C))

WHT

RED BLK

 

 

 

 

 

 

 

2

 

 

3

 

 

 

 

1

 

Outdoor fan motor

 

Color of lead wire

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED – BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK – WHT

 

11 ~ 16 Ω

 

 

V

 

 

 

U

 

 

 

 

 

WHT – RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure the resistance using a tester.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Part temperature : 14 ~ 104 °F (-10 ~ 40 °C))

 

 

 

 

 

 

 

 

 

 

 

 

 

R. V. coil (21S4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

970 ~ 1380 Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure the resistance using a tester.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Part temperature : 14 ~ 104 °F (-10 ~ 40 °C))

WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

LEV

Expansion valve coil

 

Color of lead wire

 

Normal

 

ORN

 

 

 

 

 

 

 

 

 

 

WHT – RED

 

 

 

 

 

 

 

 

 

 

 

 

(LEV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED – ORN

 

37 ~ 54 Ω

 

 

 

 

 

 

YLW

 

 

 

BRN

 

 

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YLW – BRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRN – BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

Page 22
Image 22
Black & Decker MUZ-FD09NA- U1, MUZ-FD12NA- U1 service manual Trouble Criterion of Main Parts MUZ-FD09NAMUZ-FD12NA, Wht Red