10-4. TROUBLE CRITERION OF MAIN PARTS MUZ-FD09NA MUZ-FD12NA
Part name |
| Check method and criterion |
|
|
|
|
|
|
| Figure | ||||||||
Defrost thermistor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(RT61) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ambient temperature | Measure the resistance with a tester. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
thermistor (RT65) | Refer to |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Outdoor heat ex- | board”, the chart of thermistor. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
changer temperature |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
thermistor (RT68) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Discharge tem- | Measure the resistance with a tester. Before measurement, hold the |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
perature thermistor |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
thermistor with your hands to warm it up. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
(RT62) |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Fin temperature | Refer to |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
board”, the chart of thermistor. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
thermistor (RT64) |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Measure the resistance between terminals using a tester. | WHT | RED BLK | |||||||||||||||
| (Winding temperature : | |||||||||||||||||
|
|
|
|
|
|
| 2 |
|
|
| 3 |
|
| 1 | ||||
Compressor |
| Normal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| W |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| 1.52 ~ 2.17 Ω |
|
| V |
|
|
|
| U |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Measure the resistance between lead wires using a tester. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| (Part temperature : 14 ~ 104 °F | WHT | RED BLK | |||||||||||||||
|
|
|
|
|
|
| 2 |
|
| 3 |
|
|
|
| 1 |
| ||
Outdoor fan motor |
| Color of lead wire |
| Normal |
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| W |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
| RED – BLK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BLK – WHT |
| 11 ~ 16 Ω |
|
| V |
|
|
| U |
|
|
| ||||
|
| WHT – RED |
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Measure the resistance using a tester. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| (Part temperature : 14 ~ 104 °F |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
R. V. coil (21S4) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Normal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 970 ~ 1380 Ω |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Measure the resistance using a tester. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| (Part temperature : 14 ~ 104 °F | WHT |
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
| RED |
|
|
| LEV | ||||||||
Expansion valve coil |
| Color of lead wire |
| Normal |
| ORN |
|
|
|
|
|
|
|
|
| |||
| WHT – RED |
|
|
|
|
|
|
|
|
|
|
|
| |||||
(LEV) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| RED – ORN |
| 37 ~ 54 Ω |
|
|
|
|
|
| YLW |
|
|
| BRN |
|
| BLU | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| YLW – BRN |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| BRN – BLU |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
22