7

 

 

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MUZ-FD09NA MUZ-FD12NA

 

 

 

 

 

 

 

 

 

 

 

 

 

7-1. PERFORMANCE DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) COOLING CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Indoor air

 

 

 

 

Outdoor intake air DB temperature (˚F)

 

 

 

 

 

 

IWB

 

75

 

 

85

 

 

95

 

 

105

 

 

115

 

 

 

 

 

 

(˚F)

TC

SHC

TPC

TC

SHC

TPC

TC

SHC

TPC

TC

SHC

TPC

TC

SHC

TPC

 

MUZ-FD09NA

71

11.0

6.9

0.58

10.3

6.5

0.63

9.7

6.1

0.68

9.0

5.6

0.72

8.3

5.2

0.75

 

67

10.4

7.9

0.55

9.7

7.4

0.60

9.0

6.8

0.65

8.4

6.4

0.69

7.7

5.8

0.72

 

 

 

 

 

63

9.8

8.8

0.52

9.1

8.1

0.58

8.5

7.6

0.62

7.7

6.9

0.66

7.0

6.3

0.69

 

 

 

 

 

71

14.7

8.8

0.85

13.7

8.2

0.94

12.9

7.7

1.01

12.0

7.2

1.06

11.0

6.6

1.10

 

MUZ-FD12NA

67

13.9

10.2

0.81

13.0

9.5

0.89

12.0

8.8

0.96

11.2

8.1

1.02

10.3

7.5

1.07

 

63

13.1

11.3

0.77

12.1

10.5

0.85

11.3

9.7

0.92

10.3

8.9

0.98

9.4

8.1

1.02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE : 1. IWB : Intake air wet-bulb temperature

TC : Total Capacity (x103 Btu/h)

SHC : Sensible Heat Capacity (x103 Btu/h)

TPC : Total Power Consumption (kW)

2.SHC is based on 80 ˚F of indoor Intake air DB temperature.

2)COOLING CAPACITY CORRECTIONS

Refrigerant piping length (one way : ft.)

 

 

25 (std.)

 

 

40

 

 

65

 

 

 

 

 

 

 

 

 

 

 

 

 

MUZ-FD09NA

1.0

 

 

 

0.954

 

0.878

 

 

 

 

 

 

 

 

 

 

 

 

 

MUY-FD12NA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3) HEATING CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

Indoor air

 

 

 

 

 

 

 

 

Outdoor intake air WB temperature (˚F)

 

 

 

 

 

 

IDB

 

 

 

15

 

 

25

 

35

 

 

43

 

45

 

55

 

 

(˚F)

 

TC

 

TPC

 

TC

 

TPC

 

TC

 

TPC

TC

 

TPC

TC

 

TPC

TC

 

TPC

MUZ-FD09NA

 

75

 

6.3

 

0.56

 

7.9

 

0.66

 

9.4

 

0.73

10.6

 

0.77

11.0

 

0.78

12.4

 

0.81

 

70

 

6.7

 

0.54

 

8.2

 

0.64

 

9.6

 

0.71

10.9

 

0.75

11.2

 

0.77

12.7

 

0.80

 

 

65

 

6.9

 

0.52

 

8.6

 

0.62

 

10.0

 

0.69

11.2

 

0.73

11.6

 

0.74

13.0

 

0.78

MUZ-FD12NA

 

75

 

7.9

 

0.73

 

9.9

 

0.86

 

11.8

 

0.96

13.3

 

1.00

13.7

 

1.02

15.5

 

1.06

 

70

 

8.4

 

0.71

 

10.2

 

0.84

 

12.0

 

0.93

13.6

 

0.98

14.0

 

1.00

15.8

 

1.04

 

 

65

 

8.6

 

0.68

 

10.7

 

0.81

 

12.4

 

0.91

14.0

 

0.96

14.4

 

0.97

16.2

 

1.02

NOTE : 1. IDB : Intake air dry-bulb temperature TC : Total Capacity (x103 Btu/h) TPC : Total Power Consumption (kW)

2. Above data is for heating operation without any frost.

How to operate with fixed operational frequency of the compressor.

1.Press the EMERGENCY OPERATION switch on the front of the indoor unit, and select either EMERGENCY COOL mode or EMERGENCY HEAT mode before starting to operate the air conditioner.

2.The compressor starts with operational frequency.

3.The fan speed of the indoor unit is High.

4.This operation continues for 30 minutes.

5.In order to release this operation, press the EMERGENCY OPERATION switch twice or once, or press any button on the remote controller.

9

Page 9
Image 9
Black & Decker MUZ-FD12NA- U1, MUZ-FD09NA- U1 service manual Data