Black & Decker MUZ-FD12NA- U1 Test condition, Power Supply, Operation, Operating Range

Models: MUZ-FD09NA MUZ-FD09NA- U1 MUZ-FD12NA- U1 MUZ-FD12NA

1 36
Download 36 pages 35.06 Kb
Page 5
Image 5
Test condition

Test condition

3,

4

 

 

 

 

 

 

ARI

Mode

Test

 

Indoor air condition

Outdoor air condition

 

Dry bulb (°F)

Wet bulb (°F)

Dry bulb (°F)

Wet bulb (°F)

 

 

 

 

 

 

 

 

 

"A" Cooling Steady State

 

80

67

95

(75)

 

 

at rated compressor Speed

 

 

 

 

 

 

 

 

 

 

"B-2" Cooling Steady State

 

80

67

82

(65)

 

 

at rated compressor Speed

 

 

 

 

 

 

 

 

 

SEER

"B-1" Cooling Steady State

 

80

67

82

(65)

 

(Cooling)

at minimum compressor Speed

 

 

 

 

 

 

 

 

 

Low ambient Cooling Steady State

 

80

67

67

(53.5)

 

 

at minimum compressor Speed

 

 

 

 

 

 

 

 

 

 

Intermediate Cooling Steady State

 

80

67

87

(69)

 

 

at Intermediate compressor Speed

5

 

 

 

 

 

 

 

 

Standard Rating-Heating

 

70

60

47

43

 

 

at rated compressor Speed

 

 

 

 

 

 

 

 

 

 

Low temperature Heating

 

70

60

17

15

 

 

at rated compressor Speed

 

 

 

 

 

 

 

 

 

 

Max temperature Heating

 

70

60

62

56.5

 

HSPF

at minimum compressor Speed

 

 

 

 

 

 

 

 

(Heating)

High temperature Heating

 

70

60

47

43

 

 

at minimum compressor Speed

 

 

 

 

 

 

 

 

 

 

Frost Accumulation

 

70

60

35

33

 

 

at rated compressor Speed

 

 

 

 

 

 

 

 

 

 

Frost Accumulation

 

70

60

35

33

 

 

at Intermediate compressor Speed

5

 

 

 

 

 

 

OPERATING RANGE5 : At Intermediate compressor Speed

=("Cooling rated compressor speed" - "minimum compressor speed") / 3 + "minimum compressor speed".

OPERATING RANGE

(1) POWER SUPPLY

 

Rated voltage

 

Guaranteed Voltage

 

 

 

 

 

 

 

 

208/230 V

Min.187 V 208 V 230 V Max.253 V

Outdoor unit

1 phase

 

 

 

 

 

 

 

 

 

 

 

60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

(2) OPERATION

Mode

Condition

 

 

Intake air temperature (°F)

 

 

lndoor

 

 

Outdoor

 

 

DB

 

WB

DB

 

WB

 

Standard temperature

80

 

67

95

 

Cooling

Maximum temperature

90

 

73

115

 

Minimum temperature

67

 

57

14

 

 

 

 

 

Maximum humidity

78

%

 

 

Heating

Standard temperature

70

 

60

47

 

43

Maximum temperature

80

 

67

75

 

65

 

Minimum temperature

70

 

60

14

 

13

5

Page 5
Image 5
Black & Decker MUZ-FD12NA- U1, MUZ-FD09NA- U1 service manual Test condition, Power Supply, Operation, Operating Range