Black & Decker MUZ-FD12NA- U1, MUZ-FD09NA- U1 service manual Symptom

Models: MUZ-FD09NA MUZ-FD09NA- U1 MUZ-FD12NA- U1 MUZ-FD12NA

1 36
Download 36 pages 35.06 Kb
Page 21
Image 21
Manual background

No.

Symptom

LED indication

Abnormal point/

Condition

Correspondence

Condition

 

 

 

 

 

 

 

Outdoor unit

7-time flash

Low discharge tem-

Temperature of discharge temperature thermistor has been

•Refer to 10-5.

"Check of LEV".

18

operates.

2.5 seconds OFF

perature protection

122 °F (50 °C) or less for 20 minutes.

•Check refrigerant circuit and refrig-

 

 

 

 

 

erant amount.

 

 

 

8-time flash

PAM protection PAM:

The overcurrent flows into IGBT (Insulated Gate Bipolar tran-

This is not malfunction. PAM protec-

 

 

2.5 seconds OFF

Pulse Amplitude

sistor : TR821) or when the bus-bar voltage reaches 320 V or

tion will be activated in the following

19

 

 

Modulation

more, PAM stops and restarts.

cases;

 

 

 

 

 

1 Instantaneous power voltage drop

 

 

 

 

 

(Short time power failure)

 

 

 

 

 

2 When the power supply voltage is

 

 

 

 

 

high.

 

 

 

9-time flash

Inverter check mode

The connector of compressor is disconnected, inverter check

•Check if the connector of the com-

20

 

2.5 seconds OFF

 

mode starts.

pressor is correctly connected.

 

 

 

 

Refer to 10-5.

"How to check

 

 

 

 

 

inverter/ compressor".

 

 

 

 

 

 

 

21

Page 21
Image 21
Black & Decker MUZ-FD12NA- U1, MUZ-FD09NA- U1 service manual Symptom