Outdoor fan motor does not operate, or stops immediately after starting up.

L Check of inverter P.C. board

Check the outdoor fan motor. (Refer to10-5..)

Is the fuse (F901) blown on the in- verter P.C. board?

No

Check the connection of the connectors (CN932) of the outdoor fan motor.

If the connection is poor, make it correct.

Operate the outdoor unit by starting

EMERGENCY OPERATION.

Check the LED indication on the in- verter P.C. board.

Does the LED flash 10-time?

Yes

(10-time flash)

Replace the inverter P.C. board.

Yes

 

 

Inverter P.C. board

 

(Solder side)

 

CN932

 

Check the corresponding parts

No

following LED indication.

(Refer to 10-3.)

 

28

Page 28
Image 28
Black & Decker MUZ-FD12NA- U1, MUZ-FD09NA- U1 service manual Check of inverter P.C. board, Emergency Operation