Chapter 2: Overview

Table 2-2. LES421A components.

Number in Figure

 

 

 

2-1 or 2-2

Component

Description

 

 

 

 

1

(1)

RJ-45 connector

Connects a standard Ethernet network drop using a straight-through RJ-45 male Ethernet cable.

 

 

 

 

2

(1)

5-position terminal block connector

Connects to an RS-422 or RS-485 serial device when the DB9 M (RS-232) connector is disabled.

 

 

 

 

3

(1)

DB9 male connector

Connects to an RS-232 serial device when the 5-position terminal block (RS-422/RS-485) is disabled.

 

 

 

 

4

(1)

2-wire terminal block connector

Removable 2-position terminal block with +, -, and chassis ground connections.

 

 

 

 

5

(1)

Serial Port LED

Flashes green when data is being transmitted or received on the serial port.

Lights steady green when the serial port is open.

 

 

 

 

 

 

 

6

(1)

Ethernet Link LED

Lights when a connection is made.

Flashes when there is data traffic on the Ethernet link.

 

 

 

 

 

 

 

 

 

 

Lights green continuously when the unit is initializing.

7

(1)

Ready LED

Flashes once per second when the system is operating correctly.

 

 

 

Off when something is wrong, for example, another device uses the same IP address.

 

 

 

 

8

(1)

Reset button

Used to initiate a hardware reset, enter console mode, or reload factory defaults.

 

 

 

 

2.4.2 2-Port Hardened Serial Server (LES422A)

Figures 2-3 and 2-4 show the front and top panels of the LES422A. Table 2-3 describes its components.

4

 

 

7

3

 

6

4

 

 

 

 

 

 

1

 

 

 

 

7

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

2

Figures 2-3 and 2-4. LES422A front and top panels.

Page 14

724-746-5500 blackbox.com

Page 14
Image 14
Black Box LES424A manual 2 2-Port Hardened Serial Server LES422A, LES421A components