PHONE LINE MANAGER 16 X 4

19.5 Switchhook (Flash) Timing

This is the minimum amount of time necessary to perform a switchhook. If the switchhook is pressed for less than this amount of time, the system recognizes it as a dial pulse and not as a switchhook (or flash). The “200 ms” and “300 ms” entries have been included because some phone instruments do not go onhook cleanly and this can cause an outside call to be inadvertently placed on hold when trying to hang up on the call. The longer switchhook times can help to compensate for these phones.

4.Enter the “switchhook time” code:

0 300 milliseconds

1 200 milliseconds

2 112 milliseconds

3 104 milliseconds

4 96 milliseconds

*5 88 milliseconds

6 80 milliseconds

7 72 milliseconds

8 64 milliseconds

9 56 milliseconds

19.6 Reminder Feature Timing

When a call is put on hold, this setting determines the amount of time to wait to ring the person that placed the call on hold or to ring the Operator or a Rollover Extension if the extension which placed the call on hold is not available.

5.Enter the “Reminder Feature Timing” code. This parameter sets the time for calls placed on hold by an extension.

025 seconds

150 seconds

*2 175 seconds

3300 seconds

4425 seconds

5550 seconds

6675 seconds

7800 seconds

8925 seconds

95 seconds