Chapter 3: Installation
3.2.4 Channel switching by external control
The OPTIONS port allows external control of the current channel by commands sent either via
3.2.4.1 OPTIONS port pinout
The OPTIONS port can accept either 8p8c or 10p10c connectors, as required. See Figure
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8p8c | 10p10c | Signal |
1 |
|
|
|
| 10 |
| 1 | Channel select input 1 | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | 2 | 5VDC power output (100mA max) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 | 3 | GND reference for all signals |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3 | 4 | RS232 (RXD) data receive |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4 | 5 | RS232 auxiliary data transmit (reserved) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | 6 | RS232 auxiliary data receive (reserved) |
| OPTIONS | ||||||||||||||||||
| 6 | 7 | RS232 (TXD) data transmit | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 7 | 8 | Channel select input 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8 | 9 | Channel select input 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10 | Channel select input 4 |
Figure
To connect a computer or device for remote control
1 Insert the 8p8c or 10p10c connector of the cable to the OPTIONS port on the rear panel of the unit. See Figure
USER
CONSOLE
OPTIONS
4
Figure
2 Connect the other end of the cable to a vacant serial port on the computer or to the output of the switching device.
Page 19 |