Black Box KV3404A Managing EDID video display information, Refreshing EDID information during use

Models: Black Box ServSwitch Wizard VGA (USB) KV3004A KV3204A KV3404A KV3304A

1 41
Download 41 pages 51.55 Kb
Page 22
Image 22
3.2.6 Managing EDID video display information

ServSwitch Wizard VGA (USB)

3.2.6 Managing EDID video display information

Whenever a ServSwitch Wizard VGA (USB) unit is powered on (or when the option F 2 is selected from the configuration menu), it will interrogate the connected monitor(s) to determine whether EDID (Extended Display Identification Data) information is avail- able. If EDID information is available, it will be copied and used; otherwise a default set of data, stored within the ServSwitch Wizard VGA (USB), will be substituted. You can also optionally choose to prevent the unit from seeking new EDID information and instead rely only on stored data.

EDID Emulation

The ServSwitch Wizard VGA (USB) units use an EDID Emulation feature to ensure that the collected EDID information (up to two pages) is correctly supplied to every connected computer, whether it is currently selected or not. See Figure 3-16.

Display

4

Display

3

Display

2

Display

1

INDOOR

USE

ONLY

USER

4

CONSOLE

5V

 

4A

 

 

OPTIONS

EDID

3

2

EDID

EDID

 

V4

 

V3

 

V2

 

V1

1

USB 1

 

USB 2

 

USB2.0

 

SWITCHED

EDID

Computer

Computer

Computer

Computer

4

3

2

1

Figure 3-16. How EDID information is disseminated across the computers

3.2.6.1 Refreshing EDID information during use

You can refresh the EDID information from the connected monitor(s) without the need to power cycle the ServSwitch Wizard VGA (USB).

To refresh EDID information during use

1Enter the Configuration menu (see Section 4.1 for details).

2Press F to enter the Functions menu

3Press 2 and then Enter.

4Press E and then Enter to exit the menu.

3.2.6.2 Using stored EDID information only

You can choose to prevent the unit from interrogating the video display(s) during startup. When you invoke this option, the unit will only use the EDID information that it has already stored and pass this on to the connected computers. To revert to interrogat- ing the video display, use the F 2 function discussed above.

To use the stored EDID information at the power up

1Enter the Configuration menu (see Section 4.1 for details).

2Press F to enter the Functions menu

3Press 3 and then Enter.

4Press E and then Enter to exit the menu.

Page 22