3.4 Channel switching by external control

ServSwitch™ Wizard DP USB

3.4 Channel switching by external control

The OPTIONS port featured on every Wizard DP USB allows external control of the current channel either by the optional RC4 controller, commands sent via RS-232 serial input or by switching one of the four channel select input lines. For more details about the necessary RS-232 serial cable, see A.1 Cable pin-outs.

3.4.1 OPTIONS port pinout

The OPTIONS port can accept either 8p8c or 10p10c connectors, as required.

1 10

OPTIONS

8p8c 10p10c Signal

1 Channel select input 1

12 5VDC power output (100mA max)

23 GND reference for all signals

34 RS232 (RXD) data receive

45 RS232 auxiliary data transmit (reserved)

56 RS232 auxiliary data receive (reserved)

67 RS232 (TXD) data transmit

78 Channel select input 2

89 Channel select input 3

10 Channel select input 4

3.4.1.1 Connecting a computer or device for remote control

1 Insert the 8p8c or 10p10c connector of the cable to the OPTIONS port on the rear panel of the unit.

USER

CONSOLR

NSOLE

3.4.1 OPTIONS port pinout OPTIONS

OPTIONS4

Figure 3-13. Connecting a link cable to the Options port

2 Connect the other end of the cable to a vacant serial port on the computer or to the output of the switching device.