Table 5-4 (continued). SCSI Switch commands.

6 x 4 ELECTRONIC SCSI SWITCH

Table 5-4 (continued). SCSI Switch commands.

Command

Cmd.

Example

Example Result or

 

Chars.

Command String

Response

 

 

 

 

Enable/Disable Alarm

OA

<cr>//OA0<cr>

Alarm enabled

 

 

 

 

Set Baud Rate

OB

<cr>//OB10<cr>

COM2 = 9600 bps

 

 

 

 

Set Serial-Port Mode

OC

<cr>//OC0<cr>

Daisychain enabled

 

 

 

 

Set Switch Number

OD

<cr>//OD06<cr>

Switch # = 6

 

 

 

 

Set Lock/Unlock

OP

<cr>//OP3156<cr>

Password = 3156

Password

 

 

 

 

 

 

 

Set Temperature Limit

OT

<cr>//OT45<cr>

Max. temp. = 45˚C

 

 

 

 

Report Revision

R

<cr>//R<cr>

“2024610”

 

 

 

 

Lock Serial Ports

OL

<cr>//OL3156<cr>

//OL1 pass

 

 

 

//OL0 fail

 

 

 

 

Unlock Serial Ports

OU

<cr>//OU3156<cr>

//OU1 pass

 

 

 

//OU0 fail

 

 

 

 

Report Serial-Port

OS

<cr>//OS<cr>

//OS1 lock

Lock Status

 

 

//OS0 open

 

 

 

 