Solution 64 User Guide

Inputs > Input Testing >

Walk Test All Zones

MENU 3-9-0

This menu allows you to test all zones within an area at the same time. To successfully walk test each zone, you must open and close each zone.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [3] + [9] + [0].

The keypad will display a list of areas that are available to walk test zones.

2.Use the [] and [] keys to select the area that you want to do walk test, then press [OK] to select. Alternatively, you can enter the area number, then press [OK].

The keypad will scroll all zones that you can test.

To test Z001 open then close Zone 1 Name

Press OK or MENU

To test Z002 open then close Zone 2 Name

Press OK or MENU

3.Open and close each zone that needs to be tested. A zone that has been successfully tested will no longer scroll on the keypad display.

When all zones have been tested, the keypad will display:

Selected zones have been

Tested OK

Press OK or MENU

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

Inputs > Input Testing >

Walk Test A Single Zone

MENU 3-9-1

This menu allows you to select a single zone to be tested via walk test.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [3] + [9] + [1].

The keypad will display a list of zones that are available to be tested via walk test.

2.Use the [] and [] keys to select the zone that you want to walk test, then press [OK] to select. Alternatively, you can enter the zone number, then press [OK].

The keypad will display the zone to be tested.

To test Z001 open then close Zone 1 Name

Press OK or MENU

3.Open and close the zone that needs to be tested.

When the zone has been successfully faulted and restored, the keypad will display:

Z001 Zone 1 Name

Test Successful

Press OK or MENU

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

Outputs

The Solution 64 control panel has up to a maximum of 8 outputs. 4 outputs are available as standard with an additional 4 available when the optional output expander is fitted. Your installer will advise you on the exact makeup and configuration of you system.

Outputs > Commands >

Output Status

MENU 4-0-0

This menu allows you to view the status of each output. Enter programming mode (PIN + MENU) then,

1.Ensure that the system is turned off.

2.Press [MENU] + [4] + [0] + [0].

The keypad will display a list of outputs that the status may be viewed.

3.Using the [] and [] keys, highlight the output that you want to view the status information, then press [OK] to select. Alternatively, you can enter the output number and then press [OK].

The keypad will display the following when the output is off and OK:

18

Bosch Security Systems

09/06

BLCC110U

Page 18
Image 18
Bosch Appliances 9 6 BLCC110U manual Walk Test All Zones, Walk Test a Single Zone, Output Status