Bosch Appliances DVA-08K Hot-Swappable Components, 2.5.1, Hot-Swap Capabilities, 2.5.2, 2.5.3

Models: DVA-08K

1 68
Download 68 pages 6.26 Kb
Page 18
Image 18
Hot-Swappable Components

18 en IntroductionRAID Subsystem DVA-08K Installation Manual

2.5

Hot-Swappable Components

2.5.1

Hot-Swap Capabilities

 

The subsystem comes with a number of hot-swappable components. A hot-swap component

 

is one that can be exchanged while the subsystem is still online without affecting the opera-

 

tional integrity of the subsystem. These components should only be removed from the subsys-

 

tem when they are being replaced. At no other time should these components be removed

 

from the subsystem.

2.5.2

Components

 

The following components are all hot-swappable:

 

Power supply units (PSUs)

 

Cooling fan modules

 

Hard drives

 

BBU module

2.5.3

Normalized Airflow

 

Proper subsystem cooling is referred to as “normalized” airflow. Normalized airflow ensures

the sufficient cooling of the subsystem and is only attained when all components are properly installed. Therefore, a failed component should only be hot-swapped when a replacement is available. If a failed component is removed but not replaced, permanent damage to the sub- system can result.

F.01U.027.797 V2 2008.08

Bosch Security Systems

Page 18
Image 18
Bosch Appliances DVA-08K manual Hot-Swappable Components, 2.5.1, Hot-Swap Capabilities, 2.5.2, 2.5.3, Normalized Airflow