RAID Subsystem | Hardware Installation en 23 |
|
|
3.5Rackmounting
The subsystem is easily installed into a standard
The enclosure chassis can be installed using
3.5.1 | Considerations for Installation Site and Chassis |
•
•
•
•
•
Make sure you have an appropriate site location and cables prepared with adequate lengths to connect to main power and other devices.
At least two people will be required to install the chassis. Disk drives should only be installed after the chassis is properly mounted. The chassis can weigh about 24Kgs with- out disk drives.
The following tools are necessary for mounting the chassis:
–#4
–Wrenches may be necessary, depending on the rack type
Use the included M5 or M6 screws for securing the chassis through its front mounting ears.
More details about the use of optional slide rails are given in the Installation Guide that came with the slide rail package.
3.5.2 | Mounting Holes Positions |
•
•
Integrators may design their own brackets or slide rails using the
There are six (6) mounting holes with six (6) M4 nuts near the end of the chassis on each side. Shown below are the locations of these mounting holes. (See the arrow marks in Figure 3.2). See the next diagram for another group of mounting holes on a horizontal line.
Fig. 3.1 Enclosure Side Mounting Holes (1)
•
•
Figure 3.2 shows holes that are designed for slide rail options. There are five (5) mount- ing holes for
For information on installing the chassis using the slide rails, please refer to the Installa- tion Manual that came with the kit.
Fig. 3.2 Enclosure Side Mounting Holes (2)
•Use M5 or M6