6.2.4

44 en Subsystem MaintenanceRAID Subsystem DVA-08K Installation Manual

6.2.4

Replacing the Controller Module

 

1.

Remove the failed controller module.

 

2.

Install a DIMM module on the new controller module.

 

3.

Insert the replacement controller. Align the controller module with the module bay at the

 

 

rear of the subsystem. Gently slide the controller module in.

 

4.

Fasten the hand screws. Once the controller module has been completely inserted into

 

 

the subsystem chassis, secure the controller module to the chassis by tightening the

 

 

hand screws at the sides of the controller rear panel.

 

5.

Connect the controller module cables: Reconnect all of the cables that were previously

 

 

disconnected from the controller module. These may include SCSI cables for host and

 

 

expansion connections, an RS-232C (audio jack) cable for serial port connection, and an

 

 

Ethernet cable for network connection.

 

6.

Power on: Once the new controller module has been properly installed and the cables

 

 

have been correctly connected, turn the subsystem power on.

F.01U.027.797 V2 2008.08

Bosch Security Systems

Page 44
Image 44
Bosch Appliances DVA-08K manual 6.2.4, Replacing the Controller Module