RAID Subsystem | Subsystem Monitoring en 31 |
|
|
i
Name | Color | Status |
|
|
|
POWER | Blue | ON indicates that power is being supplied to the subsys- |
|
| tem. |
|
| OFF indicates that no power is being supplied to the sub- |
|
| system. |
|
|
|
BUSY | White | Flashing indicates that there is activity on the host/drive |
|
| channels. |
|
| OFF indicates that there is no activity on the host/drive |
|
| channels. |
|
|
|
ATTENTION | Red | ON indicates that one or more component failure/critical |
|
| events have occurred. |
|
| OFF indicates that the subsystem and all its components |
|
| are operating normally. |
|
|
|
Table 4.6 LCD Panel LED Definitions
NOTICE!
The LCD panel ATTEN LED will be turned on during the power up process. The ATTEN LED will be turned off after the boot up procedure is completed correctly.
4.2.8Cooling Fan Module LED
The cooling fan module comes with a single
Fig. 4.7 Cooling Fan Module LED
RED
Status
OFF
The cooling fan module is operating normally.
ON
The cooling fan module has failed and must be replaced.
Table 4.7 Cooling Fan Module LED Definitions
The subsystem has a novel approach to stabilizing the temperature within the subsystem: When the sensors within the enclosure detect critical working conditions, such as high ambi- ent temperature or the failure of any cooling or PSU module, the system will turn the cooling fans to high speed to extract more heat. Once the ambient temperature cools down to normal or the faulty module has been replaced, the cooling fans return to normal speed.
Bosch Security Systems | F.01U.027.797 V2 2008.08 |