5.2.3

36 en Subsystem Connection and OperationRAID Subsystem DVA-08K Installation Manual

5.2.3

SCSI Termination

i

Correct SCSI termination procedures require that the last device on the SCSI bus be termi- nated. If the last device is not terminated or if devices other than the last are terminated, erratic SCSI bus behavior may occur.

An auto-detection, on-board terminator is built into the DVA-08K. You do not need to install an external terminator when a subsystem acts as the last device in the daisy chain configuration. The on-board terminator default is enabled. If the subsystem is not the last device in the daisy chain configuration, the terminator will be automatically disabled. Although it is not recom- mended, if you prefer to disable the firmware setting for the on-board terminator using the LCD keypad panel on the subsystem, RS232C terminal session, or Bosch RAIDWatch manage- ment software, the auto-detection function is also disabled.

Typically, the host computer or host adapter (SCSI card inside the PC) is the first device and some are already terminated. When installing the DVA-08K on a SCSI bus with other devices, be sure to observe the above rules regarding all devices on the SCSI bus. Consult your host computer and/or host adapter manual for additional information on correct termination pro- cedures.

NOTICE!

It is recommended not to change the firmware default setting for the SCSI terminator so the auto-detection function can operate.

F.01U.027.797 V2 2008.08

Bosch Security Systems

Page 36
Image 36
Bosch Appliances DVA-08K manual 5.2.3, SCSI Termination