Bosch Appliances FW5 software manual Audio Alarm

Models: FW5

1 100
Download 100 pages 15.84 Kb
Page 70
Image 70

70 en Alarm

Camera Browser Interface

 

 

12.3Audio Alarm

Alarms can be generated based on audio signals. Configure signal strengths and frequency ranges so that false alarms, for example, machine noise or background noise, are avoided. Set up normal audio transmission before configuring the audio alarm.

12.3.1Audio alarm

Select On for the device to generate audio alarms.

12.3.2Name

The name makes it easier to identify the alarm in extensive video monitoring systems, for example with the Bosch Video Client and the Bosch Video Management System. Enter a unique and clear name here.

12.3.3Signal Ranges

Exclude particular signal ranges in order to avoid false alarms. For this reason the total signal is divided into 13 tonal ranges (mel scale). Check or uncheck the boxes below the graphic to include or exclude individual ranges.

12.3.4Threshold

Set up the threshold on the basis of the signal visible in the graphic Set the threshold using the slide control or, alternatively, move the white line directly in the graphic using the mouse.

12.3.5Sensitivity

Use this setting to adapt the sensitivity to the sound environment and effectively suppress individual signal peaks. A high value represents a high level of sensitivity.

AM18-Q0605 v5.0 2011.07

Software manual

Bosch Security Systems

Page 70
Image 70
Bosch Appliances FW5 software manual Audio Alarm