58 en Advanced Mode

DinionHD 720p IP Camera

 

 

Actual shutter

Displays the actual shutter value from the camera to help compare lighting levels and optimum shutter speed during set- up.

Sensitivity up

In AES mode, selects the factor by which the sensitivity of the camera is increased (OFF, 2x, 3x, etc. to a maximum of 10x).

Note:

If Sensitivity up is active, some noise or spots may appear in the picture. This is normal camera behavior. Sensitivity up may cause some motion blur on moving objects.

Gain

AGC - the camera automatically sets the gain to the lowest possible value needed to maintain a good picture.

Fixed - sets Fixed gain value.

Maximum gain / Fixed gain

Selects the maximum value the gain can have during AGC operation (0 to 30 dB).

Selects the gain setting for Fixed gain operation (0 is no gain).

Actual gain

Displays the actual AGC value from the camera to help compare gain level with lighting levels and picture performance.

AR18-10-B013 v1.52 2011.06 Installation and Operation Manual

Bosch Security Systems

Page 58
Image 58
Bosch Appliances NBN-921 operation manual Actual shutter, Sensitivity up, Gain, Maximum gain / Fixed gain, Actual gain