28 en Installation | DinionHD 720p IP Camera |
|
|
5.5Alarm and relay connector
| Alarm |
|
1 | 4 |
|
2 | 5 | 5 mm |
|
| |
3 | 6 | (0.2 in) |
|
Figure 5.6 Alarm and relay connector pins
Pin | Alarm socket |
|
|
1 | Alarm in 1 |
|
|
2 | Alarm in 2 |
|
|
3 | Relay out contact 1 |
|
|
4 | Ground |
|
|
5 | Ground |
|
|
6 | Relay out contact 2 |
|
|
Alarm Input
–AWG
–Impedence: Internal
–Input voltage range:
–Input voltage treshold: low voltage 0.8 V maximum, high voltage 2.4 V minimum.
–Configurable as active low or active high.
Use the alarm input to connect external alarm devices such as door contacts or sensors. A zero potential make or break contact can be used as the actuator (use a
Relay output
–Max. wire diameter AWG
–Output relay switching capability: Max voltage 30VAC or +40 VDC. Max 0.5 A continuous, 10 VA.
–Max. 42 V allowed between camera ground and each of the relay pins.
Bosch Security Systems |