28 en Installation

DinionHD 720p IP Camera

 

 

5.5Alarm and relay connector

 

Alarm

 

1

4

 

2

5

5 mm

 

 

3

6

(0.2 in)

 

Figure 5.6 Alarm and relay connector pins

Pin

Alarm socket

 

 

1

Alarm in 1

 

 

2

Alarm in 2

 

 

3

Relay out contact 1

 

 

4

Ground

 

 

5

Ground

 

 

6

Relay out contact 2

 

 

Alarm Input

AWG 26-16 max.(0.13-1.5 mm2); cut back 5 mm (0.2 in) of insulation.

Impedence: Internal pull-up 10 kOhm to +5 VDC.

Input voltage range: -5 VDC minimum to 40 VDC maximum.

Input voltage treshold: low voltage 0.8 V maximum, high voltage 2.4 V minimum.

Configurable as active low or active high.

Use the alarm input to connect external alarm devices such as door contacts or sensors. A zero potential make or break contact can be used as the actuator (use a bounce-free contact system).

Relay output

Max. wire diameter AWG 22-28 for both stranded and solid; cut back 5 mm (0.2 in) of insulation.

Output relay switching capability: Max voltage 30VAC or +40 VDC. Max 0.5 A continuous, 10 VA.

Max. 42 V allowed between camera ground and each of the relay pins.

AR18-10-B013 v1.52 2011.06 Installation and Operation Manual

Bosch Security Systems

Page 28
Image 28
Bosch Appliances NBN-921 operation manual Alarm and relay connector, Pin Alarm socket, Alarm Input, Relay output