96 en Advanced Mode | DinionHD 720p IP Camera |
|
|
9.7Interfaces
Interfaces
>Alarm input
>Relay
>COM1
9.7.1Alarm input
Configure the alarm triggers for the camera.
Select N.C. (Normally Closed) if the alarm is to be triggered by closing the contact.
Select N.O. (Normally Open) if the alarm is to be triggered by opening the contact.
Select None to disable the input.
Name
Enter a name for the alarm input. This name can be displayed below the icon for the alarm input on the LIVEPAGE. (Do not use any special characters, for example &.)
Action
Select the camera mode to switch to when alarm input 1 is triggered.
Note:
See Section 9.6.8 Alarm Task Editor, page 95, for information on alarm actions based on alarm inputs.
9.7.2Relay
Configure the switching behavior of the relay output.
Select different events that automatically activate an output. For example, turn on a floodlight by triggering a motion alarm and then turn the light off again when the alarm has stopped.
Idle state
Select Open for the relay to operate as an N.O. contact, or select Closed if the relay is to operate as an N.C. contact.
Bosch Security Systems |