Bosch Appliances VIP X1 manual COM1, Serial port function, Camera ID

Models: VIP X1

1 144
Download 144 pages 47.21 Kb
Page 83
Image 83
COM1

VIP X1 Installation and Operating Manual

EN 83

 

 

COM1

You can configure the serial interface parameters (orange terminal block) to meet your requirements.

Note

If the VIP X1 is working in multicast mode (see page 89), the first remote location to establish a video connection to the unit is also assigned the transparent data connection. However after about 15 seconds of inactivity the data connection is automatically terminated and another remote loca- tion can exchange transparent data with the unit.

Serial port function:

Select a controllable unit from the list. If you wish to use the serial port to transmit transparent data, select Transparent. Select Terminal if you wish to operate the unit from a terminal.

Note

After selecting a unit, the remaining parameters in the window are set au- tomatically and should not be changed.

Camera ID:

If necessary, enter the ID of the peripheral you wish to control (for example a dome camera or pan/tilt head).

Bosch Security Systems 2006-12 V2.5

Configuration using a Web browser

Page 83