Bosch Appliances VIP X1 iSCSI connections malfunctions, Malfunction, Possible causes, Solution

Models: VIP X1

1 144
Download 144 pages 47.21 Kb
Page 125
Image 125
iSCSI connections malfunctions

VIP X1 Installation and Operating Manual

EN 125

 

 

Malfunction

Possible causes

Solution

The unit does not

Alarm source is not selected.

Select possible alarm sources on

report an alarm.

 

the Alarm sources configuration

 

 

page.

 

 

 

 

No alarm response speci-

Specify the desired alarm response

 

fied.

on the Alarm connections config-

 

 

uration page, change the

 

 

IP address if necessary.

 

 

 

Control of cameras

The cable connection

Check all cable connections and

or other units is not

between the serial interface

ensure all plugs are properly fitted.

possible.

and the connected unit is not

 

 

correct.

 

 

 

 

 

The interface parameters do

Make sure that the settings of all

 

not match those of the other

units involved are compatible.

 

unit connected.

 

 

 

 

The unit is not opera-

Power failure during pro-

Have the unit checked by Cus-

tional after a firm-

gramming by firmware file.

tomer Service and replace if nec-

ware upload.

 

essary.

 

 

 

 

Incorrect firmware file.

Enter the IP address of the unit fol-

 

 

lowed by /main.htm in your Web

 

 

browser and repeat the upload.

iSCSI connections malfunctions

Malfunction

Possible causes

Solution

No LUNs are dis-

Incorrect LUN mapping dur-

Check the iSCSI server configura-

played after connec-

ing iSCSI server configura-

tion and reconnect.

tion to the iSCSI

tion.

 

server.

 

 

 

 

 

„LUN FAIL“ is dis-

The LUN map was not read-

Check the iSCSI server configura-

played below a node

able as it was assigned to

tion and reconnect.

after connection to

the wrong network interface.

 

the iSCSI server.

 

 

 

 

 

LUN mapping is not

Some iSCSI systems don’t

Delete the initiator extension on the

possible.

support initiator extensions.

iSCSI settings configuration page.

 

 

 