Bosch Appliances VIP X1 manual General malfunctions, ping, Malfunction, Possible causes, Solution

Models: VIP X1

1 144
Download 144 pages 47.21 Kb
Page 124
Image 124
General malfunctions

EN 124Installation and Operating Manual VIP X1

General malfunctions

Malfunction

Possible causes

Solution

No connection

Incorrect cable connections.

Check all cables, plugs, contacts,

between the unit and

 

terminals and connections.

terminal program.

 

 

The computer's serial inter-

Check the other serial interface.

 

 

face is not connected.

 

 

 

 

 

Interface parameters do not

If necessary select a different inter-

 

match.

face and make sure that the com-

 

 

puter's interface parameters match

 

 

those of the unit. Try the following

 

 

standard parameters:

 

 

19,200 baud, 8 data bits, no parity,

 

 

1 stop bit. Next, disconnect the unit

 

 

from the power supply and recon-

 

 

nect it again after a few seconds.

 

 

 

No image transmis-

Camera error.

Connect local monitor to the cam-

sion to remote sta-

 

era and check the camera function.

tion.

 

 

Faulty cable connections.

Check all cables, plugs, contacts

 

 

 

and connections.

 

 

 

No connection estab-

The unit's configuration.

Check all configuration parame-

lished, no image

 

ters.

transmission.

 

 

Faulty installation.

Check all cables, plugs, contacts

 

 

 

and connections.

 

 

 

 

Wrong IP address.

Check the IP addresses

 

 

(terminal program).

 

 

 

 

Faulty data transmission

Check the data transmission with

 

within the LAN.

ping.

 

The maximum number of

Wait until there is a free connection

 

connections has been

and then call the sender again.

 

reached.

 

 

 

 

No audio transmis-

Hardware fault.

Check that all connected audio

sion to remote sta-

 

units are operating correctly.

tion.

 

 

Faulty cable connections.

Check all cables, plugs, contacts

 

 

 

and connections.

 

 

 

 

Incorrect configuration.

Check the audio parameters on the

 

 

Audio settings and Livepage

 

 

configuration configuration

 

 

pages.

 

 

 

 

The audio voice connection

Wait until the connection is free

 

is already in use by another

and then call the sender again.

 

receiver.

 

 

 

 

Appendix

Bosch Security Systems 2006-12 V2.5

Page 124
Image 124
Bosch Appliances VIP X1 General malfunctions, ping, Malfunction, Possible causes, Solution, Audio settings and Livepage