a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product

in good condition

no longer than 50 feet (15,2 m)

12 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 OR 16 AWG.)

Risk of Property Damage. The use of an undersized extension cord will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an exten- sion cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed.

Voltage and Circuit Protection

Refer to the Voltage and Minimum Branch Circuit Requirements under Specifications.

Certain air compressors can be operated on a 15 amp circuit if the following conditions are met.

Voltage supply to circuit must comply with the National Electrical Code.

Circuit is not used to supply any other electrical needs.

Extension cords comply with specifications.

Circuit is equipped with a 15 Amp circuit breaker or 15 Amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked “D” in Canada and “T” in the US.

If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

Compatibility

Air tools and accessories that are run off the compressor must be compatible with petroleum- based products. If you suspect that a material is not compatible with petroleum products, an air line filter for removal of moisture and oil vapor in compressed air is required.

NOTE: Always use an air line filter to remove moisture and oil vapor when spraying paint.

Location

Place the air compressor in a clean, dry and well ventilated area at least 12" (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air. Keep the compressor away from areas that have dirt and/or volatile fumes in the atmosphere. These impurities may clog the intake filter and valves, causing inefficient operation.

The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

Place the air compressor on a flat surface resting on the rubber feet and wheels.

Preparation For Use

Pre-Start Checklist (Fig. 1)

1. Ensure the On/Off switch (A) is in the OFF position.

2.Plug the power cord into the correct branch circuit receptacle. See Voltage and Circuit Protection under Installation.

3.Ensure air tank is drained, see Draining Air Tank under Maintenance.

4.Ensure the drain valve (H) is closed.

5.Ensure safety valve (G) is functioning properly, see Checking Safety Valve under Maintenance.

6.Check pump oil level, see Compressor Pump Oil under Maintenance.

Do not operate without oil or with inadequate oil. Bostitch is not responsible for compressor failure caused by inadequate oil.