Braun MCA166-USB user manual Mmcaquerypower

Models: MCA166-USB

1 72
Download 72 pages 41.23 Kb
Page 50
Image 50

MCA166-USB

Name

MMCA_QUERY_POWER

 

 

 

 

 

 

 

 

 

 

Description

The command reads the MMCA power state.

 

 

 

 

 

 

 

 

 

 

Parameter

-

 

 

 

 

 

 

 

 

 

 

Result array

Battery current [mA]

long value

 

 

 

 

 

 

 

 

 

Byte Offset 4

HV primary current [mA]

long value

 

 

 

 

 

 

 

 

 

Byte Offset 8

+12 primary current [mA]

long value

 

 

 

 

 

 

 

 

 

Byte Offset 12

-12 primary current [mA]

long value

 

 

 

 

 

 

 

 

 

Byte Offset 16

+24 primary current [mA]

long value

 

 

 

 

 

 

 

 

 

Byte Offset 20

-24 primary current [mA]

long value

 

 

 

 

 

 

 

 

 

Byte Offset 24

Battery voltage [mV]

long value

 

 

 

 

 

 

 

 

 

Byte Offset 28

HV [V]27

long value

 

 

 

 

 

 

 

 

 

Byte Offset 32

HV state

long value

 

 

 

 

 

 

 

 

 

Byte Offset 36

 

 

 

 

 

 

 

 

 

 

 

Byte Offset 40

Current high voltage [V]

 

 

 

 

 

 

 

 

 

 

Byte Offset 44

 

 

 

 

 

 

 

 

 

 

 

Byte Offset 48

Power Switches

long value

0X80

-24V

ON

 

 

 

0X40

+24V

ON

 

 

 

0X20

-12V

ON

 

 

 

0X10

+12V

ON

 

 

 

0X02

HV

ON

Byte Offset 52

Charger current [mA]

long value

 

 

 

 

 

 

 

 

 

...

 

 

 

 

 

 

 

 

 

 

 

Byte Offset 64

Battery current [mA] at stop

long value

 

 

 

 

 

 

 

 

 

Byte Offset 68

HV primary current [mA] at stop

long value

 

 

 

 

 

 

 

 

 

Byte Offset 72

+12 primary current [mA] at stop

long value

 

 

 

 

 

 

 

 

 

Byte Offset 76

-12 primary current [mA] at stop

long value

 

 

 

 

 

 

 

 

 

Byte Offset 80

+24 primary current [mA] at stop

long value

 

 

 

 

 

 

 

 

 

Byte Offset 84

-24 primary current [mA] at stop

long value

 

 

 

 

 

 

 

 

 

Byte Offset 88

Battery voltage [mV] at stop

long value

 

 

 

 

 

 

 

 

 

Byte Offset 92

HV [V]28 at stop

long value

 

 

 

 

 

 

 

 

 

Byte Offset 116

Charger current [mA] at stop

long value

 

 

 

 

 

 

 

 

 

...

 

 

 

 

 

 

 

 

 

 

 

Byte Offset 128

mca_state29

integer value

 

 

 

 

 

 

 

 

 

Return Code

see MMCA_RESET command

 

 

 

 

 

 

 

 

 

 

27multiply value with 1.2 V

28multiply value with 1.2 V

29see MMCA_QUERY_SYSTEM_DATA