Braun MCA166-USB user manual Cmdinit, Cmdstart, Cmdstop, Statestop

Models: MCA166-USB

1 72
Download 72 pages 41.23 Kb
Page 58
Image 58

MCA166-USB

APPENDIX 4 - Description of the MCA166-USB firmware functions

MCA Reset Command:

Command name

CMD_INIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

All MCA Parameters will be reset to their initial state and the spectra are cleared. The measurement

 

is aborted, but the states of the preamplifier power and the value of the high voltage are unchanged!

Command syntax

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format

integer

 

 

integer

 

integer

 

long

 

 

 

 

integer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

preamble

 

command

0

 

0

 

 

 

 

end flag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte String (HEX)

A5

5A

 

41

00

00

00

00

 

00

00

00

B9

 

9B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Used setup value

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Affected setup value

All

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MCA state

STATE_READY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MCA Acquire Commands:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command name

CMD_START

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

Depending on the value of the first parameter(cf)

the command clears the spectrum and the time or

 

not and then the measurement will be started. If the first parameter is not equal zero, the spectrum

 

and the time where cleared and the second parameter(st) is stored as start time.39

 

 

 

Command syntax

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format

integer

 

 

integer

 

integer

 

long

 

 

 

 

integer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

preamble

 

command

cf

 

st

 

 

 

 

end flag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte String (HEX)

A5

5A

 

42

00

cf

00

stl

 

..

..

sth

B9

 

9B

Used setup value

All

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Affected setup value

start time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MCA state

STATE_RUN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command name

CMD_STOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

The measurement is stopped immediately. There is no

synchronisation with the internal clock or

 

dwell time.

 

 

 

 

 

 

 

 

 

 

 

 

Command syntax

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format

integer

 

 

integer

 

integer

 

long

 

 

 

 

integer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

preamble

 

command

0

 

0

 

 

 

 

end flag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte String (HEX)

A5

5A

 

43

00

00

00

00

 

00

00

00

B9

 

9B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Used setup value

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Affected setup value

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MCA state

STATE_STOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

39 See Appendix 3

58

Page 58
Image 58
Braun MCA166-USB user manual Cmdinit, Cmdstart, Cmdstop, Statestop

MCA166-USB specifications

The Braun MCA166-USB is a compact and versatile charging device designed for modern lifestyles. This product expertly combines functionality with portability, making it an essential accessory for people on the go. One of the key features of the Braun MCA166-USB is its dual charging capability. It comes equipped with multiple USB ports, allowing users to charge various devices simultaneously, from smartphones to tablets. This multi-device functionality eliminates the need for multiple chargers cluttering your workspace or travel bag.

The device supports fast charging technology, which is particularly beneficial for users who need quick power boosts. With a maximum output of 2.4A per port, the Braun MCA166-USB ensures that your devices are energized swiftly, reducing downtime and keeping you connected during busy days. Additionally, the device is compatible with a wide range of charging protocols, offering versatility for different brands and models.

The Braun MCA166-USB features an intelligent charging system that recognizes the connected device and delivers the optimal charging current. This not only enhances the efficiency of charging but also protects your devices from any potential damage caused by overcharging.

Constructed with a sleek and sturdy design, the Braun MCA166-USB is not just about functionality; it is also aesthetically pleasing. Its compact size makes it perfect for portability, easily fitting into a pocket or small bag. The durability of the materials used ensures that the charger withstands the rigors of travel while remaining stylish.

Another highlight of the Braun MCA166-USB is its safety features. It incorporates multiple protection mechanisms, including short-circuit prevention and temperature control, ensuring a safe charging environment for your devices.

In summary, the Braun MCA166-USB emerges as an innovative solution for those seeking a reliable charging option. Its robust features, such as dual USB ports, fast charging capabilities, intelligent charging control, and safety measures, make it an ideal choice for anyone looking to stay powered up while balancing a busy lifestyle. With its sleek design and durable construction, the Braun MCA166-USB undoubtedly stands out as a multifaceted charging device for the modern user.