2 CEE Command Line Interface

NOTE

At system startup, if you try to enter privileged EXEC mode before the system has fully booted, the following message is displayed:

%Info: Please wait. System configuration is being loaded.

After the system has fully booted, a RASlog message indicates that the CEE CLI is ready to accept configuration commands.

TABLE 4

CEE CLI command modes

 

 

 

 

 

 

Command

Prompt

How to access the command mode

Description

mode

 

 

 

 

 

 

 

EXEC

switch>

Enter the cmsh command at the

Display running system information

 

 

Fabric OS prompt after you have

and set terminal line parameters.

 

 

logged in as an appropriate user.

 

Privileged

switch#

From the EXEC mode, enter the

EXEC

 

enable command.

Display and change system parameters. Note that this is the administrative mode and also includes EXEC mode commands.

Global

switch(config)#

From the EXEC mode, enter the

Configure features that affect the

configuration

 

configure terminal EXEC command.

entire switch.

 

 

 

 

Interface

Port-channel:

From the global configuration mode,

Access and configure individual

configuration

switch(conf-if-po-63)#

specify an interface by entering one

interfaces.

 

 

of the following commands:

 

 

10-Gigabit Ethernet (CEE port):

interface port-channel

 

 

switch(conf-if-te-0/1)#

interface tengigabitethernet

 

 

interface vlan

 

 

 

 

 

VLAN:

 

 

 

 

switch(conf-if-vl-1)#

 

 

 

Protocol

LLDP:

From the global configuration mode,

Access and configure protocols.

configuration

switch(conf-lldp)#

specify a protocol by entering one of

 

 

 

the following commands:

 

 

Spanning-tree:

protocol lldp

 

 

switch(conf-mstp)#

protocol spanning-tree mstp

 

 

protocol spanning-tree rstp

 

 

switch(conf-rstp)#

 

 

switch(conf-stp)#

protocol spanning-tree stp

 

16

Converged Enhanced Ethernet Administrator’s Guide

 

53-1002163-02

Page 38
Image 38
Brocade Communications Systems 53-1002163-02 manual Interface port-channel