5 End to End FCoE using FC ISLs

The following diagram shows a deployment scenario where FCoE initiators are connected to FCoE and FC targets across multiple hops of FC ISLs.

Aggregation

Switch/Router

FCoE

Storage

DCX/DCX-4s

FCoE Edge

FCoE,

Storage

Tape

Libraries

DCX FC Core

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAN

 

 

 

FC

 

 

 

 

 

 

Storage

 

 

 

 

 

 

 

Arrays

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DCX FC Edge

Fibre Channel

Data Center Bridging

Ethernet

FIGURE 3 Deploying FCoE across multiple hops of FC ISLs

FCoE Logical Port Numbering

A total of 24 FCoE logical ports on FCOE10-24 belong to 6 FCoE port groups. The port number range is 0 through 23 and these belong to 6 FCoE port groups ranging from 0 through 3, 4 through 7, 8 through 11, 12 through 15, 16 through 19, and 20 through 23. For example, the FCoE ports on a 24 port blade in the 4th slot is 4/0 through 4/23.

NOTE

This grouping is relevant only for bridging bandwidth considerations. A group of four ports that is arranged in a bank has 10Gb of bridging bandwidth.

FCoE port-to-front end TenGigabit port mapping

Each of the FCoE logical ports in VF port mode is mapped to a corresponding front end TenGigabit port such that the FCoE FLOGI received through the TenGigabit port is mapped and handled at the corresponding FCoE logical port.

32

Converged Enhanced Ethernet Administrator’s Guide

 

53-1002163-02

Page 54
Image 54
Brocade Communications Systems 53-1002163-02 FCoE Logical Port Numbering, FCoE port-to-front end TenGigabit port mapping