6. Maintenance

(8) Apply ethanol to the Felt fully, app. 2 ml, of the Encoder Cleaner.

Ethanol

0073Y

<Note>

Use ethanol of 95% or higher purity.

(9) Push the position [A] shown below with your finger to give space between the felts.

0074Y

(10)Put the Encoder to the Encoder Strip so that the Encoder Strip should run between the felts straightly, and the bottom part of the felt should touch the inside of the Encoder Cover. The felts catch the Encoder Strip when you release your finger.

Encoder Strip

Inside of the Encoder Cover

0075Y

(11)Wipe the Encoder Cleaner two or three times from the leftmost position to the right. After wiping, push the position [A] of the Encoder Cleaner to release it from the Encoder Strip.

<Note>

Keep the level of the Encoder Cleaner in wiping.

GT-3 Series

93