g Plug the machine’s power cord back into the AC power outlet first, connect all cables, and then plug in the telephone line cord.
h Turn on the machine’s power switch.
Cleaning the corona wire
If you have print quality problems or the LCD shows Drum Error, clean the corona wire as follows:
a Leave the machine turned on for 10 minutes for the internal fan to cool the extremely hot parts inside the machine.
b Press the front cover release button and then open the front cover.
c Take out the drum unit and toner cartridge assembly.
62