PLUG
COLLECTOR BOX
DRAIN TUBE (BLUE &
WHITE STRIPED)
CAP
COLLECTOR BOX
TUBE (PINK)
INDUCER HOUSING (MOLDED) DRAIN TUBE (BEHIND COLLECTOR BOX DRAIN TUBE)
COLLECTOR BOX
DRAIN TUBE (BLUE)
COLLECTOR BOX
TUBE (GREEN
ROUTES BEHIND
INDUCER)
CONDENSATE
TRAP
DRAIN TUBE
COUPLING (LEFT
DRAIN OPTION)
| ||
| ||
DRAIN TUBE | FIELD- INSTALLED | |
DRAIN TUBE | ||
½ - IN. CPVC STREET | COUPLING (LEFT | |
ELBOWS (2) FOR | DRAIN OPTION) | |
LEFT DRAIN OPTION |
|
A07274
Fig. 7 -
1.Collector Box Drain Tube
Connect collector box drain tube (blue label) to condensate trap.
NOTE: On
2.Inducer Housing Drain Tube
a.Remove and discard LOWER (molded) inducer housing drain tube which was previously connected to condensate trap.
b.Use inducer housing drain extension tube (violet label and
c.Determine appropriate length, then cut and connect tube.
d.Clamp tube to prevent any condensate leakage.
3.Relief Port Tube
a.Connect relief port tube (green label) to condensate trap.
b.Extend this tube (if required) by splicing to small diameter tube
c.Determine appropriate length, then cut and connect tube.
Condensate Trap Field Drain Attachment
Refer to Condensate Drain section for recommendations and procedures.
PLUG
COLLECTOR BOX
DRAIN TUBE (BLUE &
WHITE STRIPED)
CAP
COLLECTOR BOX
TUBE (PINK)
COLLECTOR BOX |
|
DRAIN TUBE (BLUE) | 355CAV |
CONDENSATE | |
COLLECTOR BOX |
|
TUBE (GREEN) |
|
TRAP |
|
INDUCER HOUSING |
|
(MOLDED) DRAIN |
|
TUBE (VIOLET) |
|
A07281
Fig. 8 - Alternate Trap Location
Pressure Switch Tubing
The LOWER collector box pressure tube (pink label) is factory connected to the pressure switch and should not require any modification.
NOTE: See Fig. 7 or 8 or tube routing label on main furnace door to check for proper connections.
Upper Collector Box and Inducer Housing (Unused) Drain
Connections
Upper Collector Box Drain Connection
Attached to the UPPER collector box drain connection is a
NOTE: See Fig. 7 or 8 or tube routing label on main furnace door to check for proper connections.
Upper Inducer Housing Drain Connection
Attached to the UPPER (unused) inducer housing drain connection is a cap and clamp. This cap is used to prevent condensate leakage in this application. Ensure this connection is capped.
NOTE: See Fig. 7 or 8 or tube routing label on main furnace door to check for proper connections.
Condensate Trap Freeze Protection
Refer to Condensate Drain Protection section for recommendations and procedures.