Bunn LCC-2 C1 r un, C2 r un, C3 r un, C4 r un, Calibrating The Dispenser, Calibration Mode

Models: LCC-2

1 26
Download 26 pages 22.61 Kb
Page 20
Image 20
CALIBRATING THE DISPENSER

CALIBRATING THE DISPENSER

NOTE: The LCA-2 LP is calibrated at the factory and does not normally need to be re-calibrated. To enter the Calibration Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position and then hold the “MENU” switch down for 10 seconds.

LCD DISPLAY

C1C1 r unC1 2 2 r C2 r unuC3  r unn

MENU (-) (+)

C1 CALIBRATION MODEof the Concentrate Pumps.Concentrate Pumps.2C4 r un 2

MENU (-) (+)

C2Manual backgroundManual background r Manual backgrounduManual backgroundn

MENU (-) (+)

C2Manual backgroundManual backgroundManual background2Manual background 2

MENU (-) (+)

C3 Manual backgroundManual background r Manual backgrounduManual backgroundn

MENU (-) (+)

C3 Manual backgroundManual background1.Manual background0Manual background8

MENU (-) (+)

CALIBRATION MODE

 DESCRIPTION

Left (Regular) Pump Cal.

Set PRIME-NORMAL-RINSE switch

 

to PRIME position. Press and hold

 

Regular Dispense Switch until pump

 

stops (20 sec.) Refer to Field Calibration

 

of the Concentrate Pumps.

Left (Regular) Pump Cal.

Enter mL collected from the 20 sec.

 

test above.

 

Default = 22

 

Range = 18 - 26mL

Right (Decaf) Pump Cal.

Set PRIME-NORMAL-RINSE switch to

 

PRIME position. Press and hold Decaf

 

Dispense Switch until pump stops (20

 

sec.) Refer to Field Calibration of the

 

Concentrate Pumps.

Right (Decaf) Pump Cal.

Enter mL collected from the 20 sec.

 

test above.

 

Default = 22

 

Range = 18 - 26mL

Left (Regular) Water Rate

Set PRIME-NORMAL-RINSE switch to

 

RINSE position. Press and hold Regular

 

Dispense Switch until flow stops (20

 

sec.) Refer to Field Calibration of the

 

Concentrate Pumps.

Left (Regular) Water Rate

Enter Liters collected from the 20 sec.

 

test above.

 

Default = 1.08

 

Range = 0.95 - 1.12 Liters

C4Manual backgroundManual background r Manual backgrounduManual backgroundn

MENU (-) (+)

Right (Decaf) Water Rate

Set PRIME-NORMAL-RINSE switch to

 

RINSE position. Press and hold Decaf

 

Dispense Switch until flow stops (20

 

sec.) Refer to Field Calibration of the

 

Concentrate Pumps.

20

39288 072707

 

Page 20
Image 20
Bunn LCC-2 C1 r un, C2 r un, C3 r un, C4 r un, Calibrating The Dispenser, Calibration Mode, Lcd Display,  Description