Bunn LCC-2 service manual Field Calibration of the Concentrate Pumps & Dispenser Flow Rates

Models: LCC-2

1 26
Download 26 pages 22.61 Kb
Page 24
Image 24

Field Calibration of the Concentrate Pumps & Dispenser Flow Rates

The factory set default values for the Pump & Dispenser Flow Rates are very accurate and typically do not need to be field calibrated. However, if the mix ratio accuracy is ever in question, this procedure can be used to reca- librate the unit in the field.

Equipment Required:

50 to 100 ml graduated cylinder, with 1 ml graduations.

1500 to 2000 ml graduated container.

NOTE: You can calibrate either the Concentrate Pump or the Dispenser Flow Rate independently. Simply scroll through the menu screen to the desired section and perform only those steps. (refer to Calibrating the Dis- penser)

Calibrating the Concentrate Pumps.

Regular Coffee - Left Concentrate Pump Calibration

1.Open the door of the dispenser and select PROGRAM on the Mode Selector Switch.

2.Depress and Hold the MENU switch for approximately 10 sec. The unit will display “C1 run” when it has entered the Calibration Mode.

3.Select PRIME on the Function Selector Switch.

4.Place a container under the left Dispense Tip and depress the Regular dispense switch until a steady stream of concentrate comes out the tip (5 to 10 seconds).

5.Stop priming and allow the tip to stop dripping. Discard the concentrate collected.

6.Place a 50 ml graduated cylinder under the Left Dispense Tip.

7.Press & Hold the Regular dispense switch. The dispenser will display a 20 second count down timer and then shut the pump OFF automatically. Release the dispense switch.

8.Keep the graduated cylinder under dispense tip until all the concentrate has dripped out.

9.Measure the volume of concentrate collected in the graduated cylinder.

The acceptable range for the volume of concentrate collected is 16 - 26 ml

10.If the amount collected is not within the acceptable range, empty the graduated cylinder and repeat STEPS 6 – 9.

11.If the amount collected is still not within range, replace the pump tubing with a new Tube Kit, (refer to the Tube Replacement Instructions).

12.When satisfied with the volume of concentrate collected, press the MENU switch. The current Calibration volume “C1 XX” will be displayed.

13.Use the (-) / (+) keys to adjust number displayed to the amount measured in STEP 9.

Decaffeinated Coffee - Right Concentrate Pump Calibration

Depress the MENU switch to display the Decaffeinated Concentrate Pump calibration menu “C2 run”. Repeat STEPS 3 – 13 above for the right side “Decaf” pump.

Calibrating the Dispenser Flow Rates.

Regular Coffee - Left Dispenser Flow Rate Calibration

1.Select RINSE on the Function Selector Switch.

2.Press the MENU switch to display the Regular Coffee Flow Rate calibration menu “C3 run

3.Place a container under Left Dispense Tip and depress the Regular dispense switch until a steady stream of water comes out the tip (5 to 10 seconds).

4.Stop dispensing and allow the tip to stop dripping. Discard the water collected

(Continued Next Page)

24

39288 072707

 

Page 24
Image 24
Bunn LCC-2 Field Calibration of the Concentrate Pumps & Dispenser Flow Rates, Calibrating the Concentrate Pumps