CALIBRATING THE DISPENSER (Cont.)
LCD DISPLAY
C41. 0 8
MENU
C5 06 5
MENU
C5 CHL
MENU
CALIBRATION MODE | DESCRIPTION |
Right (Decaf) Water Rate | Enter Liters collected from the 20 sec. |
| test above. |
| Default = 1.08 |
| Range = 0.95 - 1.12 Liters |
Cooler Control Temperature | Used to set the Target Temperature for |
| the Product Cabinet. |
| Default = 65°F (18°C) |
| Range = 50° - 75°F (10° - 24°C) |
Maximum Cooling Mode | SetProductCabinetTargetTemperature |
| to 50°F (10°C). Then continue to hold |
| the decrease |
| will display “CHL”. Chiller will now |
| attempt to cool the product cabinet to |
| 45°F (7°C). To disable this mode, hold |
| the increase (+) switch for 10 sec. Then |
| adjust to the desired Cabinet Temp. |
| NOTE: All Cabinet Temperature |
| Warnings are disabled when in the |
| Max. Cooling Mode. |
C6 20 0
MENU
C7 Eng
MENU
Pump “OFF” Delay | Delays the Pump turn off after a |
| dispense. |
| Default = 200 |
| Range = 1 - 999 mSec. |
English or Metric Mode | Used to select the desired units. |
| Default = English |
| Eng for English |
| S.I. for Metric |
C8 Ex x
MENU
C9 - - -
MENU
Error Code Memory | Display cycles through the last (3) |
| Error Codes. |
| Erase by holding both the Decrease |
| & Increase (+) switches for 10 sec. |
Reset Factory Defaults | Resets all set up values to the Factory |
| Default setting. |
| Hold both Increase (+) and Decrease |
|
LC xx
Displays Software Version # -
Exits To Home View After 3 Seconds.
MENU
21 | 39288 072707 |
|