The Ring Statistics Screen

3.6.1HSIM-F6 FDDI Ring Statistics Screen Fields

The HSIM-F6 FDDI Ring Statistics screen allows the user to monitor the current HSIM-F6 operational status.

The following list describes the Ring Statistics screen fields:

RING STATE

Displays the current ring state. The possible ring states are as follows:

Ring-Op - The ring is functioning correctly.

Isolated - The HSIM-F6 is not attached to the ring.

Non-Op - The HSIM-F6 is attempting to enter the ring.

• Detect -

The claim (beacon) process of the FDDI ring

 

protocol has exceeded one second. There may be a

 

problem.

Non-Op-Dup - The ring failed to complete the claim (beacon) process. This usually indicates a duplicate FDDI address.

Ring-Op-Dup - The ring is operational, but a duplicate FDDI address may be present somewhere on the network.

Directed - The claim (beacon) process did not complete within ten seconds. The HSIM-F6 is sending directed beacons to indicate a problem.

• Trace -

A problem has been detected with the HSIM-F6 or

 

the nearest active upstream neighbor (NAUN). A

 

trace is being sent to notify the nearest active

 

upstream neighbor of the problem.

RING-OP COUNT

The Ring-Op Count keeps track of the number of times the FDDI ring has initialized since the last time the HSIM-F6 (or host device in which it resides) was reset. If this number grows steadily over a brief period of time, it signifies the ring is unstable.

HSIM-F6 User’s Guide

3-11

Page 35
Image 35
Cabletron Systems BRIM-F6 manual HSIM-F6 Fddi Ring Statistics Screen Fields