Chapter 3: Local Management
3-6 HSIM-F6 User’s Guide
HSIM-F6 Configuration
Select this menu item to display the HSIM-F6 Configuration screen. This
screen allows the user to view the operating requirements that the
HSIM-F6 advertises to all other stations when it first enters the FDDI ring
and to set the interval that the HSIM-F6 sends Neighbor Information
Frames (NIFs).
Full Duplex Configuration
Select this menu item to display the Full Duplex Configuration screen. This
screen allows the user to configure the HSIM-F6 to operate in full duplex
mode.
FDDI/Ethernet Translation Configuration
Select this menu item to display the FDDI/Ethernet Translation
Configuration screen. This screen allows the user to assign specific FDDI
to Ethernet frame translations.