change with each scan.

Appendices

Although it is the same negative film, the colors of the preview image

change with each scan.

Cause:

The exposure function is set to auto color adjustment

Solution:

In the exposure adjustment dialog, click the check box to

 

remove the check mark beside the auto color adjustment

 

option and drag the slider to the middle. (p. 70)

 

 

A scan with the image type set to black and white results in an image

that is whited out or too dark

Cause:

Threshold setting is too high or low

Solution:

Adjust the threshold setting. (p. 69)

 

 

Black border around film included in scanned image

Cause:

Scan area not set

Solution:

Set the scan area. (p. 41)

 

 

Cannot freely specify the scan area in the preview window

Cause:

Fixed aspect ratio selected

Solution:

Reset aspect ratio to normal setting. (p. 45)

 

 

Scanning is taking a long time

Cause:

Scan resolution is set too high

Solution:

Lower the scan resolution to the minimum setting and

 

rescan.(p. 32)

 

 

Image Quality Problems

Scan quality is poor

Cause:

Scan resolution is too low

Solution:

Raise the scan resolution and rescan.(p. 32)

 

 

Image is blurred

 

Cause 1:

Focus setting was incorrect in manual focus mode

 

Solution:

Refocus in manual focus mode or use the autofocus mode.

 

 

(p. 72)

 

 

 

 

Cause 2:

Film was shot out of focus

 

 

 