Field Test Unit Software

7.7.2 “T” - TIME

This command enables the user to check and/or reset the logger’s time and date. The Canon X-07’s date and time MUST be set accurately for this pro- cedure. If the Canon’s time/date needs to be changed type “t” to reset it, (see below under X-07 Commands).

EXAMPLE:

 

Press “T”

 

FTU display

responds:

10:58:28

10:45:21

87/05/29

87/05/28

logger

canon

Press Return or Put

If the date on the logger side is as desired then press RETURN to exit. If not the press Put - “P” to set the logger’s date to that of the Canon.

7.7.3 “d” - DISPLAY *

This command causes the FTU to display current information from the logger on:

Cycle time of the logger

Log size (number of bytes used per log)

• Log interval in minutes and seconds

Time of the first log, the number of logs made and the number of full days the logger has been recording

EXAMPLE:

Press shift-D (“d”) FTU display responds: 1 second logger

1 byte log size

1 min 0 second log interval First log at 12:09:00 87/05/29 3 logs 0 days press RETURN

3 6