Field Test Unit Software

7.7.4 “r” - RESET *

This command resets the logger data storage to an original state. All data is lost and the logger starts logging immediately.

7.7.5 “j” & “a” - JUMP TO LOG & ADDRESS toggle *

These two commands are used together to view data in the logger memory. By pressing “j” the user can access specific logs. Selection of a log number will cause the FTU to display the logged data. Use of the cursor key pad wilI enable the user to move through the logs.

By pressing “a” the user can interchange the bottom line from an address dis- play to that of the loggers time reading at each specific log. If the screen is cleared and set up prior to entering “j” then the FTU will display the logged data in actual units rather than raw bytes.

7.7.6 “D” - DATA

This command will cause the FTU to prompt “Data Buffer (0-7)”. After receiving the desired buffer number the FTU will then display information on that buffer pointer from the logger.

7.7.7 “J” - JUMP to ADDRESS

Jump to address pointed to by the start, end or current pointer, (this infor- mation can be displayed by the above command). The user will be required to enter in the desired buffer number (0-7). The user can select the current, end or start buffer by pressing “S”-start, “E”-end or “C”-current.

7.8 X-07 DIRECT COMMANDS FROM FTU-PROM

7.8.1 “t”

-

TIME

 

 

 

To reset the

X-07’s

internal clock/calendar type

“t”. The

new date if required

is entered

by writing

over the old date and then

pressing

“RETURN”.

Section 7. FTUC COMMANDS

3 7

Page 43
Image 43
Canon Model 6401 B manual X-07 Direct Commands from FTU-PROM, Time