Field Test Unit Software
memory locations that the display will skip forward or backwards to when the Up arrow or Down arrow is pressed.
This step size can be saved in a screen format file.
The SPACEBAR will reset the screen to its initial state.
7.6 SCREEN FORMAT FILES
The
Warning: Use of a filename containing the letters “FTU” may cause the
FTU to lock up on power on.
7.7 COMMANDS TO MODIFY DATA LOGGER
The
7.7.1 “P” - Put
This command allows the user to change the values of the loggers RAM memory. Up to eight values can be changed at one command by typing con- secutive values separated by comma’s.
EXAMPLE:
Press “P”
FTU responds “?”
Type O,O,O,O <RET> <RET>
The value 0 will be entered in the RAM from the current address upwards. i.e. If the FTU was at address 128 the value 0 should appear in address 128 - 132.
Section 7. FTUC COMMANDS | 35 |