RIG MACHINE COMPONENTS Ð Refer to instructions on page 5, Fig. 6-8, and Carrier certi®ed drawings for ma- chine component disassembly.

IMPORTANT: Only a quali®ed service technician should disassemble and reassemble the machine. After reas- sembly, the machine must be dehydrated and leak tested.

When rigging components separately, the open drive (17EX) motor must be removed to avoid overturning.

Do not attempt to disconnect ¯anges while the machine is under pressure. Failure to relieve pressure can result in personal injury or damage to the unit.

Before rigging the compressor, disconnect the wires leading from the power panel to the control center at the power panel.

NOTE: Wiring for sensors must be disconnected. Label each wire before removal (see Carrier certi®ed drawings).

Detach all transducer and sensor wires at the sensor, then clip all wire ties necessary to remove the wires from the heat exchangers.

19EX

 

 

 

 

 

LEGEND

 

 

 

1

Ð Refrigerant Liquid Line to Economizer/

15

Ð

Motor Sight Glass (Not Shown)

27

Ð

Oil Cooler

 

 

Storage Vessel

16

Ð

Oil Filter

28

Ð

Isolation Valves (Not Shown)

2

Ð

Cooler Suction Pipe

17

Ð

Oil Level Sight Glasses (2)

29

Ð

Refrigerant Filter Drier

3

Ð

Compressor Suction Elbow

18

Ð

Cooler Relief Valves (Not Shown)

30

Ð

Local Interface Display Control Panel

4

Ð

Condenser

19

Ð

Oil Heater (Not Shown)

31

Ð

Economizer/Storage Vessel

5

Ð

Condenser Discharge Pipe

20

Ð

Auxiliary Power Panel

32

Ð

Rigging Guide (Not Shown)

6

Ð

Compressor Discharge Elbow

21

Ð

(Field Wiring Terminals)

33

Ð

Economizer/Storage Vessel

7

Ð

Guide Vane Actuator

Pumpdown Unit (Not Shown)

34

Ð

Relief Valves

8

Ð Economizer Gas Line to Compressor

22

Ð

Low-Side Float Box Cover

Cooler

9

Ð

Gear Inspection Cover

23

Ð

Refrigerant Liquid Line to Cooler

35

Ð

High-Side Float Box Cover

10

Ð

2-Stage Hermetic Compressor

24

Ð

Oil Drain and Charging Valve

36

Ð

Take-Apart Connections

11

Ð Condenser Waterbox Vent (Not Shown)

25

Ð

Oil Pump

37

Ð

Cooler Waterbox Vent

12

Ð

Condenser Marine Waterbox

26

Ð

Refrigerant Charging/Service

38

Ð

Cooler Marine Waterbox

13

Ð

Hermetic Compressor Motor

 

 

Valve 10 (Not Shown)

39

Ð

Cooler Waterbox Drain

14

Ð Compressor Motor Terminal Box

 

 

 

40

Ð

Condenser Waterbox Drain

 

 

(Not Shown)

 

 

 

 

 

 

Fig. 2 Ð Typical 19EX Installation

4

Page 4
Image 4
Carrier 17 installation instructions Typical 19EX Installation